ADDENDUM
DS-400 Installation to Uniden Chassis using D2824 PLL Chip

INSTALLATION #16

ALIGNMENT PROCEDURE #8

 

Example: President AR-144

 

IMPORTANT
The Uniden Chassis requires the DIGALOG Mod Kit P.N. 2824X to attain maximum VCO frequency range. Installations made without this Mod Kit will yield fair results with average frequency ranges. Mod Kits are available from Digalog or your local dealer.

Range without 2824X . . . . . . . . . . 26.750 - 27.750
Range with 2824X . . . . . . . . . . . . .26.350 - 28.000