Uniden
PRO710E (UT-316)
Documentation Project
CBTricks.com
ALIGNMENT OF P.L.L. PORTION
Test Equipment Required
a. |
AC Power Supply (120V, 60Hz) |
b. |
DC Voltmeter (10V maximum, 100K ohm/V) |
Alignment Procedure
STEP |
PRESET TO |
ADJUSTMENT |
REMARKS |
1 |
TX
Mode |
L702 |
Connect DC Voltmeter to TP3 (Lead of R59). Adjust for approx. 4. 5V on DC Voltmeter |
2 |
RX
Mode |
L701 |
Same as step 1 |
ALIGNMENT OF RECEIVER PORTION
Test Equipment Required
a. |
RF
Signal Generator (27 MHz Band, 1000 Hz, |
b. |
AF VTVM |
c. |
Dummy Load (8 ohm, 5 watts, resistive) |
d. |
AC Power Supply (120 V, 60 Hz) |
e. |
RF Voltmeter |
Alignment Procedure
STEP |
PRESET TO |
ADJUSTMENT |
REMARKS |
1 |
RX
Mode |
L1,
L2, L3 |
Connect
RF SSG to Ant Connector (J501) and set it 27.185MHz. |
2 |
Same
as Step 1 |
VR1
|
Set
the RF Signal Generator to 1000uV |
3 |
Same as step 1 |
VR2 |
Set
the RF Signal Generator to 100uV |
4 |
Same
as Step 1 |
L651 |
Connect
RF Voltmeter to TP1 (Lead of R11). |
Disclaimer: Although the greatest care has been taken while compiling these documents,
we cannot guarantee that the instructions will work on every radio presented.