Uniden HR2510
Documentation Project

CBTricks.com

PLL Alignment
Test Equipment Required
DC Power Supply (13.8V) Oscilloscope
DC Voltmeter Frequency Counter
Dummy Load (50 ohm)

STEP
SETTINGS CONNECTION
ADJUST
ADJUST FOR
1.
PASW :OFF
MODE SW :AM
RIT : Middle Position
Freq. : 28MHz
Dummy Load (50 ohm)
Connect an Frequency Counter to TP306.
 L315
Adjust for 6.200MHz ± reading on the Frequency Counter.
2.
Same as above Connect the Frequency Counter to TP304.
L318
Adjust for 38.695MHz ± 20 Hz reading on the Frequency Counter.
3.
Freq. 29.6999MHz Connect a DC voltmeter to TP303.
L317
Adjust for 6.5 ± 0.1 V reading on the DC Voltmeter.
4.
Mode: RX,CW
Freq. : 28MHz
Connect the Frequency Counter to TP1.
L117
Adjust for 10.6950MHz ± 20 Hz reading on the Frequency Counter.
5.
Mode: RX,LSB Same
L118
Adjust for 110.6925 MHz (-40Hz to + 0Hz) reading on the Frequency Counter.
6.
Mode: RX,USB Same
L116
Adjust for 1.0.6975 MHz ± 20 Hz reading on the Frequency Counter.
7.
Mode: TX,USB Connect the Frequency Counter to TP5.
VR111
Adjust for 38.6975MHz ± 20Hz reading on the Frequency Counter.

 


Copyright © 1998,1999,2000, 2002 CBTricks.com

Disclaimer: Although the greatest care has been taken while compiling these documents,

we cannot guarantee that the instructions will work on every radio presented.