Section 3
ALIGNMENT PROCEDURE #6
This section applies to chassis using the NDC 40013 PLL chip.
Alignment: Align L01 as per the general alignment procedure described in general alignment procedure.

Fig. 29 - Parts Location 40013 Chassis

NOTE: This chassis has no down mixer adjustment. Because Y01 has been changed, the following adjustments will be necessary:
1. Adjust L05 for correct AM frequency.
2. Adjust L04 for correct LSB frequency.

This completes ALignment Procedure #6.

NOTE: If L6 has no effect on the LSB frequency. 003 is most likely faulty.